Transactions of the American Society of Heating and Ventilating Engineers, 2. köideThe Society, 1896 |
From inside the book
Results 1-5 of 51
Page 11
... proper amount of air to be supplied per minute per person to crowded rooms . It was found that the amounts recommended by authorities varied from four to 60 cubic feet per minute for buildings such as schools , churches , and public ...
... proper amount of air to be supplied per minute per person to crowded rooms . It was found that the amounts recommended by authorities varied from four to 60 cubic feet per minute for buildings such as schools , churches , and public ...
Page 15
... proper to take what is generally accepted as a minimum for hospitals - 3,000 cubic feet per bed per hour . I would put no restrictions on the method of admitting the air . I would , however , try to bar all furnaces in which there is ...
... proper to take what is generally accepted as a minimum for hospitals - 3,000 cubic feet per bed per hour . I would put no restrictions on the method of admitting the air . I would , however , try to bar all furnaces in which there is ...
Page 16
... proper direction , by the general public . The number and salary of these inspectors can be determined by the number of buildings in any state requiring their attention . They should be required to pass an examination before the board ...
... proper direction , by the general public . The number and salary of these inspectors can be determined by the number of buildings in any state requiring their attention . They should be required to pass an examination before the board ...
Page 18
... mechanical means , and that the same can be provided without incurring un- reasonable expense , such inspector may direct a fan or other mechanical means of a proper construction to be provided within 18 PROCEEDINGS OF THE.
... mechanical means , and that the same can be provided without incurring un- reasonable expense , such inspector may direct a fan or other mechanical means of a proper construction to be provided within 18 PROCEEDINGS OF THE.
Page 19
... proper water closets , earth closets , or privies for the reasonable use of the persons admitted to such public building , or of the pupils attending such schoolhouse . Sec . 41. Every public building and every schoolhouse shall be ...
... proper water closets , earth closets , or privies for the reasonable use of the persons admitted to such public building , or of the pupils attending such schoolhouse . Sec . 41. Every public building and every schoolhouse shall be ...
Contents
3 | |
6 | |
8 | |
20 | |
26 | |
30 | |
31 | |
40 | |
172 | |
196 | |
203 | |
206 | |
207 | |
221 | |
227 | |
229 | |
49 | |
68 | |
86 | |
109 | |
111 | |
119 | |
130 | |
144 | |
157 | |
161 | |
235 | |
241 | |
246 | |
248 | |
Other editions - View all
Common terms and phrases
absorbed air furnace air supply amount annual meeting apparatus asbestos Barron board of managers boiler building Cary cast iron cent chimney church coal coil committee connection considered cooling surfaces cost cubic feet damper deal degrees direct radiation discussion draft ducts economical electric heating energy expansion expansion joints experience factor of safety fan heater fittings floor flue furnace gauge heater heating and ventilating horse power hot air hot water hour house heating humidity inches inlet installed J. A. Harding Jellett matter method mineral wool moisture motion paper plant pounds practice President:-The pressure Prof Quay question radiator relative humidity secretary semi-annual meeting society standard steam heating steam pipe t₁ temperature tests thing tion topics tube valve velocity ventilating engineers vote wall water hammer water heating Wolfe:-I XXII.-TOPIC York
Popular passages
Page 18 - ... from effluvia arising from any drain, privy, or other nuisance, and shall be provided within reasonable access with a sufficient number of proper...
Page 19 - Every factory in which five or more persons are employed, and every factory, workshop, mercantile or other establishment or office in which two or more children, young persons or women are employed, shall be kept in a cleanly state and free from effluvia arising from any drain, privy or other nuisance...
Page 19 - Whenever it shall appear to an inspector of factories and public buildings that further or different sanitary provisions or means of ventilation are required in any public building or schoolhouse in order to conform to the requirements of this act and that the same can be provided without incurring unreasonable expense, such inspector may issue a written order to the proper person or authority directing such sanitary provisions or means of ventilation to be provided, and they shall thereupon be provided...
Page 19 - Every public building and every school-house shall be kept in a cleanly state and free from effluvia arising from any drain, privy, or other nuisance, and shall be provided with a sufficient number of proper water closets, earth closets or...
Page 18 - ... gases, vapors, dust, or other impurities generated in the course of the manufacturing process or handicraft carried on therein that may be injurious to health.
Page 19 - ... be provided without excessive expense, such inspector may direct a fan or other mechanical means of a proper construction to be provided within a reasonable time, and such fan or other mechanical means shall be so provided, maintained and used.
Page 76 - ... of the energy of the heat thus communicated; and that a corresponding machine, or the same machine worked backwards, may be employed to produce cooling effects, requiring about the same expenditure of energy in working it to cool the same substance through a similar range of temperature. When a body is heated by such means about...
Page 50 - ... the parties of the second part for the purchase of the property above described, "Now, therefore, for and in consideration of the sum of Ten Dollars ($10.00) in hand paid by the parties of the second part to the parties of the first part...
Page 19 - ... fine not exceeding one hundred dollars ; but no criminal prosecution shall be made for any such violation unless such employer shall have neglected for four weeks to make such changes in his factory or workshop as shall have been ordered by an inspector of factories by a notice in writing delivered to or received by such employer.
Page 18 - ... that such inhalation could be to a great extent prevented by the use of a fan or other mechanical means...