Peidetud väljad
Raamatud Books
" ... working pressure which exceeds the maximum anticipated surface pressure, including one equipped with pipe rams, one with blind rams, and one... "
Water Pollution, 1969: Hearings, Ninety-first Congress, First Session, on S ... - Page 978
by United States. Congress. Senate. Committee on Public Works. Subcommittee on Air and Water Pollution - 1969 - 1584 lehte
Full view - About this book

Code of Federal Regulations: Containing a Codification of Documents of ...

2001 - 656 lehte
...system shall be installed consisting of at least three remote-controlled, hydraulically operated BOP's including at least one equipped with pipe rams, one with blind rams, and one annular type. (f) Tapered drill-string operations. Prior to commencing tapered drillstring operations,...
Full view - About this book

The Code of Federal Regulations of the United States of America

1996 - 600 lehte
...removed shall consist of the following: (1) Three remote-controlled, hydraulically operated preventers including at least one equipped with pipe rams, one with blind rams, and one annul«type. Minorais MonQ0<Hneot Service, Interiof (2) When a tapered string la used, the minimum...
Full view - About this book

The Code of Federal Regulations of the United States of America

2001 - 648 lehte
...floor. This control station shall be in a readily accessible location away from the drilling floor. (4) A drilling spool with side outlets, if side outlets are not provided in the body of the BOP stack, to provide for separate kill and choke lines. (5) A choke line and a kill line...
Full view - About this book

The Code of Federal Regulations of the United States of America

2003 - 638 lehte
...floor. This control station shall be in a readily accessible location away from the drilling floor. (4) A drilling spool with side outlets, if side outlets are not provided in the §250.1611 body of the BOP stack, to provide for separate kill and choke lines. (5) A choke line and...
Full view - About this book

Water Pollution - 1969, Hearings Before the Subcommittee on Air and Water ...

United States. Congress. Senate. Committee on Public Works - 1969 - 1642 lehte
...preventers of adequate capacity, including one equipped with pipe rams and one with blind rams: (b) a drilling spool with side outlets if side outlets...preventer body; (c) a manifold ; and (d) a "fill-up" line. All blowout preventers will be actuated and/or tested frequently and not lew than once each week while...
Full view - About this book

Santa Barbara Oil Spill: Hearings Before the Subcommittee on Minerals ...

United States. Congress. Senate. Committee on Interior and Insular Affairs. Subcommittee on Minerals, Materials, and Fuels - 1969 - 202 lehte
...capacity, including at least one equipped with pipe rams, one with blind rams, and one hydril type; (b) a drilling spool with side outlets if side outlets...preventer body; (c) a manifold, and (d) a fill-up line. Blowout preventers and related control equipment shall be pressure tested when installed, before drilling...
Full view - About this book

Notice to Lessees and Operators of Federal Oil and Gas Leases in the Outer ...

Geological Survey (U.S.). Branch of Oil and Gas Operations. Pacific Region - 1971 - 56 lehte
...surface pressure, including one equipped with pipe rams, one with blind rams, and one hydril type; (2) a drilling spool with side outlets, if side outlets are not provided in the blowout preventer body; (3) a choke manifold; (4) a kill line; and (5) a fill-up line. C. Intermediate Casing. Before drilling...
Full view - About this book

Environmental Conservation, the Oil and Gas Industries, 1. köide

National Petroleum Council. Committee on Environmental Conservation--the Oil and Gas Industries - 1971 - 580 lehte
...surface pressure, including one equipped with pipe rams, one with blind rams and one bag -type • A drilling spool with side outlets if side outlets are not provided at the blowout-preventer body • A choke manifold to permit control of the rate of flow of the unloading...
Full view - About this book

Environmental Conservation, the Oil and Gas Industries, 2. köide

National Petroleum Council. Committee on Environmental Conservation--the Oil and Gas Industries - 1972 - 458 lehte
...anticipated surface pressure, including one equipped with pipe rams, one with blind rams and one bag-type • A drilling spool with side outlets if side outlets are not provided at the blowout -preventer body • A choke manifold to permit control of the rate of flow of the unloading...
Full view - About this book

Outer Continental Shelf Oil and Gas Development: Hearings Before the ...

United States. Congress. Senate. Interior and Insular Affairs Committee - 1974 - 1254 lehte
...surface pressure, including one equipped with pipe rams, one with blind rams, and one bag-type,- (2) a drilling spool with side outlets, if side outlets are not provided in the blowout preventer body; (3) a choke manifold; (4) a kill -line; and (Sì a fill-up line. 10-2 Testing. Ram-type blowout preventers...
Full view - About this book




  1. My library
  2. Abi
  3. Advanced Book Search
  4. Download EPUB
  5. Download PDF