FORM C-SECTION 12. No......... of 19 REGISTRATION OF DEATH. Registration Division of Name and surname of deceased. When died. Sex (male or female.) Age. Rank or profession. Where born. Certified cause of death and duration of illness. Name of physician (if any.) Religious denomination. Description and residence of informant. Remarks. I hereby certify the foregoing to be true and correct to the best of my knowledge and belief. Given under my hand at the day of 19 Informant. I hereby certify the foregoing to be the true and correct. original entry of death returned to me on the above mentioned date. Given under my hand at the day of 19 Registrar. I hereby certify the foregoing to be a true and correct certificate of the cause of the death of the person therein CHAPTER 7. An Ordinance respecting the Inspection of Steam Boilers and the Examination of Engineers Operating the Same. SHORT TITLE. 1. This Ordinance may be cited as "The Steam Boiler Short title. Ordinance." N.W.T., c. 17, s. 1. INTERPRETATION. 2. In this Ordinance unless the context othe. wise re- Interpretaquires tion. 1. The expression "boiler" does not include boilers used "Boiler.” for heating water for domestic purposes or low pressure steam heating boilers unless the pressure exceeds fifteen pounds per square inch or railway locomotive or steam-boat boilers but means and includes all other steam boilers and every part thereof or thing connected therewith and all apparatus and things attached to or used in connection with any such boiler; 2. The expression owner means and includes any person, firm or corporation, the owner or lessee of a boiler and the manager or other head officer in charge of the business of any such firm or corporation; "Owner." 3. The expression "engineer" means any person having “Engineer.” charge of or operating a steam boiler under the provisions of this Ordinance; 4. The expression "inspector" means any inspector of "Inspector.” steam boilers appointed by the Commissioner of the Yukon CommisTerritory under the provisions of this Ordinance. N.W.T., sioner." c. 17, s. 2. INSPECTION OF STEAM BOILERS. 3. The Commissioner of the Yukon Territory may appoint Appointment an inspector or inspectors of steam boilers for the Territory of inspectors. for the purpose of carrying out the provisions of this Ordinance and may fix the remuneration to be paid such inspector or inspectors. N.W.T., c. 17, s. 3. Inspectors to have no interest in 4. No person holding the office of inspector under the provisions of this Ordinance shall be either directly or in- sale of boilers directly interested in the sale of boilers or steam machinery. machinery. N.W.T., c. 17, s. 4. or steam Oath of office to be taken. Duties of inspectors. Certain boilers exempted 5. Every inspector appointed under the provisions of this Ordinance shall before entering upon the performance of his duties take and subscribe an oath that he will faithfully and impartially perform the duties of his office. N. W. T. c. 17, s. 5. 6. The inspectors appointed under this Ordinance shall— (a) Inspect all new steam boilers within their respective districts before the same are used; (b) Once at least in each year subject all boilers within their district to hydrostatic pressure test; (c) Satisfy themselves by a thorough examination inside and out and by a hammer test after the hydrostatic pressure that the boilers are well made and of good and suitable material; (d) See that the openings for the passage of water and steam respectively and all pipes and tubes exposed to heat are of proper dimensions and free from obstruction; (e) See that the flues are circular in form; (f) Satisfy themselves that the friction (fire line) of the furnace is at least two inches below the prescribed minimum water line of the boiler; (g) See that the arrangements for delivering the feed water are such that the boilers cannot be injured thereby ; (h) Satisfy themselves that such boilers and their steam (i) See that the safety valves are of suitable dimensions (k) See that the boiler is provided with a sufficient (1) Satisfy themselves that adequate and certain provision has been made for an ample supply of water to feed the boiler at all times so that in high pressure boilers the water shall not be less than four inches above crown of flue sheet in upright boilers; (m) Satisfy themselves that means for blowing out are provided so that mud, sediment or scale may be removed while the boiler is under steam. N.W.T., c. 17, s. 6. 7. The provisions of this Ordinance respecting the inspection of boilers shall not apply to any boiler insured and Ordinance. inspected by any duly incorporated boiler insurance com- from operation pany doing business in Canada if the owner or owners of of this such boiler shall when required by an inspector appointed under the provisions of this Ordinance produce the certificate of inspection from such company. N.W.T., c. 17, s. 7. S. For the purpose of seeing that the provisions of this Inspectors Ordinance are complied with any of the inspectors appoint- may inter ed under this Ordinance may at any reasonable hour enter upon any lands or into any building where any steam boiler is operated. (2.) Any person interfering with or obstructing any inspector in the performance of his duties under this Ordinance shall be guilty of an offence and liable on summary conviction to a penalty not exceeding $100. N.W.T., c. 17, s. 8. annually. 9. Every owner of a boiler shall cause it to be inspected Boilers to be at least once in each and every year by an inspector appoint- inspected ed under the provisions of this Ordinance and shall pay to such inspector a fee of $10 for such inspection, such fee to be forwarded by the inspector to the Territorial Treasurer to be credited to the general revenue fund of the Territory. (2.) Upon the completion of any inspection the inspector Certificate shall issue to such owner a certificate of such inspection in to issue. accordance with form "A" in the schedule hereto. (3.) Such certificate shall be produced at any time by the Production owner upon the demand of an inspector appointed under thereof. the provisions of this Ordinance. (4) Any one who employs a person to operate a steam boiler who has not a certificate or permit under this Ordinance shall be guilty of an infraction of this Ordinance. N.W.T., c. 17, s. 8. tests. 10. In subjecting to hydrostatic tests boilers usually de- Hydrostatic signated as high pressure inspectors shall assume one hundred and twenty-five pounds to the square inch as the maximum pressure allowable as a working pressure for new boilers of forty-two inches diameter, made in the best manner of plates one-fourth of an inch thick of good materials. N.W.T., c. 17, s. 10. of boiler. 11. Inspectors shall rate the working pressure of all Working boilers according to their strength as compared with the pressure standard provided in the next preceding section, but the working pressure allowed in the operation of any boiler shall not exceed three-fourths of the hydrostatic test pressure to which such boiler has been subjected at the time of the inspection. N.W.T., c. 17, s. 11. 12. In addition to the annual inspection of all boilers Owner to required by this Ordinance it shall be the duty of each in- repair boiler when required |