Peidetud väljad
Raamatud Books
" ... shall have landings or balconies not less than six feet in length and three feet in width, guarded by iron railings not less than three feet in height, and embracing at least two windows at each story and connecting with the interior by easily accessible... "
Statutes of the Province of British Columbia - Page 110
by British Columbia - 1913
Full view - About this book

Annual Report, 2. köide;38. köide

New York (State). Board of Charities - 1906 - 1550 lehte
...width, guarded by iron railings not less than three feet in height, and embracing at least two windows at each story, and connected with the interior by easily accessible and unobstructed openings aijd the balconies or landings shall be connected by iron stairs not less than twenty-four inches wide,...
Full view - About this book

Annual Report of the Bureau of Labor Statistics of the State of ..., 19. köide

New York (State). Bureau of Labor Statistics - 1902 - 794 lehte
...width, guarded by iron railings not less than three feet in height, embracing at least two windows at each story and connected with the interior by easily...unobstructed openings. The balconies or landings shall be couuectod by Iron stairs, not less than eighteen inches wide, with steps of not less than six inches...
Full view - About this book

Annual Report, 9. köide

New Jersey. Bureau of Industrial Statistics - 1886 - 490 lehte
...constructed, guarded by iron railings not less than three feet in height, and taking in at least two windows at each story, and connected with the interior by easily accessible and unobstructed openings ; and the said fire-escapes shall connect by iron stairs not less than twenty-four inches wide, the...
Full view - About this book

Biennial Report of the Department of Statistics for ...

Indiana. Department of Statistics - 1898 - 880 lehte
...at each story and connecting with the interior by easily accessible and unobstructed openings, and the balconies or landings shall Be connected by iron stairs, not less than eighteen inches wide; the steps not .to be less than six inches tread, placed at a proper slant, and protected by a well-secured...
Full view - About this book

National Convention of Factory Inspectors in the United States Held at ...

1887 - 430 lehte
...constructed, guarded by iron railings not less than three feet in height, and taking in at least two windows at each story, and connected with the interior by easily accessible and unobstructed openings; and the said fire-escape shall connect by iron stairs, not less than twenty-four inches wide, the steps...
Full view - About this book

Annual Report of the Department of Inspection of Workshops ..., 5. köide

Ohio. Department of Inspection of Workshops, Factories and Public Buildings - 1889 - 286 lehte
...constructed, guarded by iron railings not less than three feet in height, and taking in at least two windows at each story, and connected with the interior by easily accessible and unobstructed openings; and the said fire-escape shall connect by iron stairs, not less than twenty-four tnches wide, .the...
Full view - About this book

Laws of the State of New York

New York (State) - 1889 - 932 lehte
...each Tldedstory and connecting with the interior by easily accessible and unobstructed openings; and the balconies or landings shall be connected by iron stairs, not less than twenty-four inches wide, the steps to be not less than six inches tread, placed at not more than an...
Full view - About this book

Annual Report of the Factory Inspectors of the State of New York ..., 4. number

New York (State). Office of Factory Inspectors - 1890 - 346 lehte
...at each story and connected with the interior by easily accessible and unobstructed openings ; and the balconies or landings shall be connected by iron stairs, not less than twenty-four inches wide, the steps to be not less than six inches tread, placed at not more than an...
Full view - About this book

Biennial Report

Minnesota. Department of Labor and Industry - 1890 - 856 lehte
...at each story and connecting with the interior by easily accessible and unobstructed openings, and the balconies or landings shall be connected by iron stairs, not less than twenty-four inches wide, the steps not to be less than six inches tread, placed at not more than an...
Full view - About this book

Report

Connecticut. Dept. of Factory Inspection - 1890 - 110 lehte
...at each story and connecting with the interior by easily accessible and unobstructed openings, and the balconies or landings shall be connected by iron stairs, not less than twenty-four inches wide, the steps not to be less than six inches tread, placed at not more than an...
Full view - About this book




  1. My library
  2. Abi
  3. Advanced Book Search
  4. Download EPUB
  5. Download PDF